Proton dose verification passes conventional gamma despite stopping-power model differences
Across four proton plans, all 12 recalculations passed 3%/3 mm gamma, but stopping-power choices shifted distal range by up to 1.9 mm.
Across four proton plans, all 12 recalculations passed 3%/3 mm gamma, but stopping-power choices shifted distal range by up to 1.9 mm.
In 20 prostate patients with hip replacements, implant-trained synthetic CT models closely reproduced CT dose, but two cases with rectal air had outliers.
Among 36 MR-Linac consortium experts, 86% reported access to the technology, but only 28% treated head and neck cancer on the platform.
Across 149 cervical radiotherapy fractions, adding ultrasound to CBCT improved uterocervix visibility but increased correct plan selection by only one percentage point.
In TARGET, focal VMAT or HDR brachytherapy boosts achieved 98.5% three-year control within treated prostate lesions, while four recurrences arose outside the boost.
With structured sexological support, median sexual function scores increased from 4.0 after chemoradiotherapy to 12.5 at one year, without a control group.
Among 307 patients with extensive-stage SCLC, overall survival did not significantly differ between consolidative and progression-triggered thoracic RT, including after matching.
In 376 spinal treatment sites, initial setup error was unrelated to pain severity but differed by spinal level and immobilization.
Among 85 radiation oncologists, nearly half reported age-based chemotherapy omission, while only 25% routinely used geriatric screening.
In STEP, three-fraction preoperative stereotactic radiotherapy achieved 100% six-month local control and 7% one-year radiation necrosis in 63 patients.
EANO reached consensus on 53 statements covering radiation necrosis diagnosis, advanced imaging, corticosteroids, bevacizumab, surgery and other treatment options.
In 46 lung cancer patients, combined functional planning reduced high-functioning lung doses by approximately 1 Gy but modestly increased heart and spinal cord exposure.
Conditioned medium from proton-irradiated chondrosarcoma cells reduced survival to 79% in chondrocytes and 59% in endothelial-like cells under different dose conditions.
Across 401 non-spinal prostate cancer bone metastases, SBRT achieved 93.3% three-year local control, with higher dose and SIB associated with better progression-free survival.
In 22 spinal targets, a dedicated planning system reduced spinal cord D2% by 2.6–2.7 Gy versus general-purpose planning without compromising PTV coverage.