KEY POINTS
- This methodology study evaluated AI-assisted contour quality assurance using data from NRG-GU010 (NCT05050084), an ongoing randomized phase III trial of genomically stratified treatment for unfavorable intermediate-risk prostate cancer. Of 579 submitted cases, 578 were analyzed: an initial 51-case cohort underwent adjudicated expert consensus review, while 527 subsequent cases were assessed in a larger workflow-validation cohort. The investigation evaluated contour QA performance, not the oncological outcomes of NRG-GU010.
- The screening system compared submitted contours with independently generated AI segmentations. Investigators used an FDA-cleared auto-segmentation platform with four geometric metrics: Dice similarity coefficient, Hausdorff distance, mean distance to agreement, and percentage volume change. Each structure received a score of 1 (per protocol), 2 (acceptable variation), or 3 (unacceptable deviation) according to prespecified thresholds. The primary workflow objective was to identify clinically consequential score-3 errors requiring expert attention.
- In the 51-case consensus cohort, AI demonstrated high sensitivity but imperfect agreement with expert assessment. It identified all four unacceptable OAR deviations (sensitivity 100%, 95% CI 40–100%). For target volumes, no score-3 cases were present; when acceptable variations and unacceptable deviations were combined, AI detected 11/12 flagged target cases (sensitivity 91.7%), with 85% specificity. Quadratic-weighted agreement with expert consensus was κ=0.71 for OARs and κ=0.53 for target volumes.
- The larger 527-case cohort showed complete detection of the few clinically unacceptable deviations. AI flagged all 5/5 score-3 target-volume deviations (sensitivity 100%, 95% CI 48–100%) and all 4/4 score-3 OAR deviations (sensitivity 100%, 95% CI 40–100%). Negative predictive value was 100% for both endpoints. However, the small number of major errors produces wide confidence intervals, and these results cannot establish that the system will reliably detect every important contouring mistake in future submissions.
- High sensitivity came at the cost of substantial false-positive screening. Case-level specificity was 69% for target volumes but only 25% for OARs, corresponding to AI flagging approximately 31% and 75% of cases, respectively. Consequently, most OAR cases would still require expert review under the evaluated thresholds, limiting the potential reduction in review workload. The system is better characterized as a prioritization tool than as a method for eliminating manual contour QA.
- The analysis identified clinically important causes of disagreement between AI and human reviewers. False-positive alerts occurred when automated segmentation struggled with unusual bladder anatomy or CT artifacts from hip prostheses. Conversely, one acceptable-variation target error involving pelvic nodal contouring was missed because its geometric discrepancies did not exceed the selected thresholds. This highlights an important limitation of purely geometric comparison: the clinical relevance of an error depends on its anatomical location and relationship to the treatment dose.
- The validation strategy did not establish independent clinical ground truth. The first cohort used consensus from participating experts, while the second used a single principal investigator per case, with different definitions of a positive screening result. Thresholds had been developed using previously reviewed prostate cases, and performance was not assessed against an independently adjudicated reference in the larger cohort. The authors propose incorporating dose-distribution information and extending validation to other disease sites, where contouring variability may be substantially greater.
CLINICAL TAKEAWAY
AI-assisted contour comparison detected all observed major target and OAR deviations in the larger NRG-GU010 validation cohort, supporting its potential role in centralized radiotherapy trial QA. However, specificity was particularly low for OARs, and only nine clinically unacceptable deviations were available for sensitivity estimation. The current evidence supports AI as an adjunct for prioritizing expert review, not as a replacement for independent contour assessment.
SOURCE
International Journal of Radiation Oncology, Biology, Physics