Online pelvic ART adds about 14 minutes, mostly for editing and optimization

Gynecologic online ART added 13.7 minutes from adaptation start to plan approval, with contour editing and optimization consuming 71% of that time.

KEY POINTS

  • The authors developed an in-house console timer that records a predefined sequence of adaptive RT events, stores fraction-specific settings, and exports structured Excel tables. ART-specific time was defined as the interval from switching into ART mode until final plan approval, excluding positioning, initial IGRT, post-adaptation IGRT, and beam delivery.
  • After successful testing on 100 simulated fractions, the timer was used clinically in 38 online adaptive pelvic fractions from nine patients: eight with postoperative endometrial cancer and one with uterine carcinosarcoma. All received 45 Gy in 25 fractions with FBCT-guided VMAT adaptation.
  • Mean ART-specific extra time was 13.7 minutes (95% CI 13.0–14.5), within a mean total session time of 21.8 minutes. Adaptation therefore accounted for 62.9% of the recorded treatment session.
  • Plan optimization was the largest individual component at 3.8 minutes, accounting for 27.7% of ART-specific time. CTV modification required 3.4 minutes and OAR modification 2.6 minutes.
  • Manual CTV/OAR editing together accounted for 43.3% of adaptive time. When combined with optimization, these activities consumed 71.1% of the entire ART-specific interval, clearly identifying the main workflow bottlenecks.
  • Additional post-adaptation IGRT required another 1.8 minutes but was deliberately excluded from the formal ART-specific interval. The authors therefore note that the true additional workload compared with conventional IGRT is approximately 14 minutes or more.
  • The analysis was limited to nine patients on one CT-linac, lacked matched non-adaptive treatment times, and relied on manual keypress timestamps. Two dual-timer sessions differed by as much as 80 seconds, supporting future automated capture directly from console or DICOM logs.

CLINICAL TAKEAWAY

For online adaptive pelvic RT, the main opportunity to shorten treatment is not beam delivery but contour review/editing and optimization. A standardized event-based timing framework may help departments audit their own adaptive workflows, although these exact times should not be generalized across platforms or staffing models.

SOURCE

Technical Innovations & Patient Support in Radiation Oncology

Browse more research Suggest a correction