KEY POINTS
- This retrospective single-center planning study evaluated 21 patients with head and neck cancer previously treated with pencil-beam scanning proton therapy. All received single-phase simultaneous integrated boost prescriptions of 66–70 Gy(RBE) in 33–35 fractions. For each patient, investigators generated paired reference and Spot Delete plans in RayStation V23b, maintaining identical beam arrangements, optimization objectives, robustness settings, and dose constraints to isolate the dosimetric effect of the Spot Delete technique.
- Spot Delete selectively removed proton spots whose Bragg peaks terminated within a superficial 5-mm skin rind outside the clinical target volumes. After spot removal, plans were reoptimized to restore target coverage. Skin evaluation focused on a 5-mm-deep surface structure extending to within 5 cm of the CTVs. Dose and dose-averaged linear energy transfer (LETd) were calculated using the clinical Monte Carlo engine, with a fixed RBE of 1.1 for dose reporting. Dose×LET volume histograms (DLVHs) were generated to characterize the joint distribution of dose and LET, rather than evaluating either parameter independently.
- Spot Delete consistently reduced skin exposure to moderate-to-high dose combined with elevated LET. The dominant reduction occurred where dose was ≥10 Gy(RBE) and LETd was ≥3.0 keV/μm. Across all 21 patients, the mean reduction in skin volume simultaneously exposed above these thresholds was 10.5 ± 6.8 cm³, representing approximately 2.1% of the evaluated skin volume. Every patient demonstrated reduced exposure. At progressively higher LET thresholds of 4.0 and 5.0 keV/μm, the corresponding mean reductions were approximately 1.5 and 0.26 cm³, respectively.
- Dose×LET difference mapping identified a statistically consistent region of reduced exposure that conventional DVHs did not clearly reveal. The analysis combined paired Wilcoxon testing, Benjamini–Hochberg false-discovery-rate correction (q≤0.05), large effect-size filtering (Cohen's d≤−0.8), and spatial-contiguity analysis. A single dominant contiguous region of reduced elevated-LET exposure was identified. The result remained consistent when the LET threshold was varied between 2.5 and 4.0 keV/μm, indicating that the finding was not dependent on one arbitrarily selected LET boundary.
- Conventional skin DVH differences were comparatively modest. Mean changes with Spot Delete relative to reference planning were −0.92 ± 0.60 Gy(RBE) for skin D50%, −0.93 ± 0.75 Gy(RBE) for D10%, and −0.64 ± 0.66 Gy(RBE) for D1%. These changes were difficult to appreciate in conventional dose-only comparisons, whereas DLVH analysis demonstrated a reproducible reduction in skin volume receiving both elevated LET and clinically relevant dose. This illustrates how plans with similar physical-dose distributions may differ in their LET characteristics.
- Target coverage was preserved despite the redistribution of proton spots. Across the evaluated CTVs, mean differences between Spot Delete and reference plans were −0.08 ± 0.15 Gy(RBE) for D95%, −0.16 ± 0.28 Gy(RBE) for D98%, and −0.07 ± 0.16 Gy(RBE) for D2%. These changes were small relative to the prescribed target dose. However, the present study did not perform a formal robustness comparison, so preservation of nominal coverage should not be interpreted as proof of equivalent robustness under setup and range uncertainties.
- The clinical significance of the elevated-LET reduction remains unknown. The identified dose–LET region was selected using biologically plausible thresholds rather than validated skin-toxicity endpoints. No patient-level dermatitis outcomes, dose–LET toxicity model, or clinical comparison of reference and Spot Delete treatment was performed. The study also used fixed-RBE dose reporting and one LET formalism, without evaluating variable-RBE dose distributions. Its retrospective design, 21-patient sample, and single-institution planning approach require external validation before the derived thresholds can guide routine clinical decisions.
CLINICAL TAKEAWAY
Spot Delete proton planning consistently reduced skin exposure to concurrent moderate-to-high dose and elevated LET while preserving nominal target coverage in head and neck cancer. Dose×LET difference mapping revealed these changes more clearly than conventional DVH analysis, supporting its potential value in biologically informed proton plan evaluation. However, the identified exposure thresholds are not validated predictors of dermatitis, and clinical benefit remains to be demonstrated.